Products Services References Knowledge base About Contact
PL EN DE
Hoymiles · Inverters

Hoymiles HIT

Three-phase hybrid inverter 5-20 kW (Low Voltage)

TypeHybrid
Phases3-phase
AC power5-20 kW
MPPT2-4 (20 A)
Battery40-60 V (LV)
ProtectionIP66

Hoymiles HIT-(5-20)L-G3 three-phase hybrid inverters rated 5-20 kW, working with low-voltage 40-60 V batteries (lithium-ion or lead-acid). From 2 to 4 MPPT inputs rated 20 A, DC/AC oversizing up to 200%, a built-in meter with bypass up to 50 A, parallel connection of up to 10 inverters and switchover to backup power under 10 ms. Smart EMS energy management and monitoring via the S-Miles cloud.

Models

Eight models 5-20 kW.

Match the inverter power to the size of the installation. All models feature 20 A MPPT inputs, support for 40-60 V batteries, switchover to backup power under 10 ms and IP66 protection.

ParameterHIT-5L-G3HIT-6L-G3HIT-8L-G3HIT-10L-G3HIT-12L-G3HIT-15L-G3HIT-17L-G3HIT-20L-G3
Rated AC power (W)50006000800010,00012,00015,00017,00020,000
Max. apparent AC power (VA)55006600880011,00013,20016,50018,70022,000
Recommended max. PV power (W)10,00012,00016,00020,00024,00030,00034,00040,000
Number of MPPT22334444
Max. AC output current (A)8.31013.316.7202528.333.3
Max. charge/discharge current (A)120150190210250300350350
Capabilities

Key features.

2-4 MPPT with 20 A input
From 2 to 4 MPPT trackers rated 20 A; a 150-900 V voltage range makes design on difficult roofs easier.
5-20 kW power
Eight power models with DC/AC oversizing up to 200% and parallel connection of up to 10 inverters (on-grid and off-grid).
Low-voltage batteries
Supports lithium-ion and lead-acid batteries 40-60 V, charging with self-adaptation to the BMS.
10-year warranty, service in PL
Official service in Poland and 24/7 monitoring.
EMS energy management
A smart EMS integrates a generator, heat pump and controllable loads; DRM support.
Switchover under 10 ms
Fast switchover to backup power, 100% unbalanced load and a peak up to 200% for 10 s.
Technical data

Specification.

Parameters shared across the entire HIT-(5-20)L-G3 series. Values that differ between models are in the comparison table above.

Type of inverterHybrid, 3-phase
Battery typeLithium-ion / lead-acid
Battery voltage40-60 V (low-voltage)
Battery communicationCAN, self-adaptation to BMS
Max. DC voltage1000 V
MPPT voltage range150-900 V
Start-up voltage150 V
Max. current per MPPT20 A
DC/AC oversizingUp to 200%
Grid type3L/N/PE, 380/400 V (266-480 V)
Grid frequency50/60 Hz
Backup output (peak)200% of rated power for 10 s
Switchover to backup powerUnder 10 ms
Max. AC bypass current50 A
Max. efficiency98.2-98.5%
MPPT efficiency99.9%
Parallel connectionUp to 10 inverters
CoolingNatural convection + smart fan
TopologyTransformerless, high-frequency
Dimensions (W/H/D)539 / 696 / 232 mm
Weight41 kg
Operating temperature-25 to +65 °C
Protection ratingIP66
ProtectionsAFCI (optional), anti-islanding, SPD DC/AC type II, insulation detection, RCMU
CommunicationRS485, Wi-Fi / Ethernet / 4G (optional)
MonitoringS-Miles cloud, app
CertificatesEN 50549, VDE-AR-N 4105, IEC 62109-1/-2
Downloads